L b t series doors if firelite or other 3 hour listed glazing material is used.
Maximum glass in b rated door.
Fire resistance rated glazing in excess of 100 square inches 0 065m 2 shall be permitted in fire door assemblies when tested as components of the door assemblies and not as glass lights and shall have the maximum end temperature rise of 450 degrees f 250 degrees c in accordance with 716 5 5.
Note many code are outlawing the use of wire glass due to the hazards of injury from glass breakage.
5268 square inches with the width and or height of exposed glass not to exceed 109 3 4.
Some local building codes do not recognize the use of glass lights in 3 hour fire doors.
To fire rated glass in doors 2012 ibc limits size of fire rated glass in doors the 2012 ibc limits the size of fire protection rated glass such as safety wired glass and safety glass ceramic used in 60 and 90 minute doors to 100 sq.
1296 square inches with the width and or height of exposed glass not to exceed 54.
For listed 1 4 wire glass the maximum sizes are.
Wire glass 100 square inches is max exposed glass when wire glass is used.
Wire glass not approved for use in 3 hour fire doors.
This applies to all hourly ratings a.
Ul labels are also discussed.
3 hour doors are not permitted to have fire protection rated glass.
20 45 minute doors still require fire protection rated glass up to the maximum size.
Limited to one 1 light per door leaf with a maximum of 100 square inches of exposed glass.
If the door serves as a horizontal exit door in a fire wall it is fur ther restricted to 100 sq.
All glass being used in a fire rated opening must be an approved listed glazing material.
Inches with no dimension exceed ing 10 inches.
A recently finalized revision to the ibc model building code limits the size of fire protective glazing such as safety wired glass and safety ceramic used within vision panels for 60 or 90 minute temperature rise doors to no more than 100 square inches whether or not sprinklers are present.
Maximum width of 12 305 mm or height of 33 838 mm.
Glass lights are available in fire rated t series doors.
A recently finalized revision to the ibc model building code limits the size of fire protective glazing such as safety wired glass and safety ceramic used within vision panels for 60 or 90 minute temperature rise doors to no more than 100 square inches whether or not sprinklers are present.
Maximum glass light size for a 90 minute 1 1 2 hour door depends on the type of glass being installed.
60 and 90 minute doors to 100 sq.